Model | AD-15-100-700-U1P1 | AD-25-150-900-U1P1 | AD-36-200-1200-U1P1 | |||
OUTPUT | Output Voltage | 10-54Vdc | ||||
Max Output Voltage | 58Vdc | |||||
Ncn-load Output Voltage | OVdc | |||||
Output Current | 100-700mA | 15O-9OOmA | 200-1200mA | |||
Output Power | 1-15W | 1.5-25W | 2-36W | |||
Fluctuation Depth | Almost flicker-free / High frequency exemption assessment level | |||||
Dimming Range. | 0~100%, 0.01% dimming depth | |||||
PWM Dimming Frequency | ≤3600Hz | |||||
Currcnl Accuracy | ±5% | |||||
Ripple & htoisc | ≤2V | |||||
INPUT | Dimming Interface | 0-10V(1-10V/PWM/RX), Push DIM | ||||
Input Volt* | 100-277Vac ±10%, (Max. 90-305Vac) | |||||
Frequency | 50/60HZ | |||||
Input Current | 115Vac≤0.2A, 230Vac≤0.12A, 277Vac≤0.1A | 115Vac≤0.3A, 230Vac≤0.2A, 277Vac≤0.15A | 115Vac≤0.45A, 230Vac≤0.25A, 277Vac≤0.2A | |||
Power Factor | PF>0.97/115Vac, PF>0.9/230Vac, PF>0.88/277Vac (full load) |
PF>0.97/115Vac, PF>0.93/230Vac, PF>0.85/277Vac (full load) |
PF>0.95/115Vac, PF>0.9/230Vac, PF>0.85/277Vac (full load) |
|||
THD | <16%/115Vac, <20%/230Vac, <29%/277Vac (full load) |
<16%/115Vac, <20%/230Vac, <22%/277Vac (full load) |
||||
EHicienqdtyp.l | 82% | 85% | 88% | |||
Inrush Currentftyp.l | Cold start 8A at 230Vac (twidth=75μs measured at 50% Ipeak) | Cold start 10A at 230Vac (twidth=75μs measured at 50% Ipeak) | Cold start 20A at 230Vac (twidth=75μs measured at 50% Ipeak) | |||
Ant« Sur9c | L-N: IkV | |||||
Leakage Current | <0.5mA/230Vac | |||||
W/IRCh.MEMT | Working Temperature | ta: -30°C ~ 55°C tc: 75°C | ||||
Working Humidity | 20 ~ 95%RH, non-condensing | |||||
Storage Temp., Humidity | -40°C ~ 80°C, 10~95%RH | |||||
Temp. Cocfhoent | ±0.03%/°C (0-50°C) | |||||
Vibration | 10~500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
PROTECTION | O^er*heot Protection | Intelligently adjusting or turning off the output current if the PCB temperature ≥110°C. And the output current will be restored automatically when the temperature comes normal |
||||
Over Load Protection | Shut down the output when current load ≥102%, auto recovers | |||||
Short Circuit Proteclicn | Shut down automatically if short circuit occurs, auto recovers | |||||
Non-load Protccticn | Shut down the output if no load, auto recovers when load back to normal | |||||
SAFETY & EMC | Withstand Voltage | I/P-O/P: 3750Vac | ||||
Isolation Resistance | I/P-O/P: 100MΩ/500VDC/25°C/70%RH | |||||
Safety Standards | CE | European Union | EN 61347-1. EN 61347-2-U. EN 62493 | |||
UL | America | UL8750 | ||||
EMC Emission | CE | European Union | EN l£C 55015. EN IEC 61000-3-2, EN 61000-3-3 | |||
UL | America | FCC part 15B | ||||
EMC Immunity | EN 61000-4-2.3,4.5,6,8.11 EN 61547 | |||||
Strobe Test Standard | IEEE 1789 | |||||
OTHERS | Dimension | 175×44×30mm(L×W×H) | ||||
Packing | 178×48×33mm(L×W×H) | |||||
Weight(G.W.) | 175g±10g |
Q1: Can you do OEM or ODM Services?
A: Yes, we can, just send your requirements to us.
Q2: What is the MOQ?
A: Small order welcome, MOQ=1PC.
Q3: What about the lead time and shipment?
A: Standard ( popular model ) can be ship within 2 day, bulk order can be delivered within 10~35 days.
For shipping, we often use DHL, FedEx, UPS, and TNT. For bulk order, we recommend to send goods by Air or by Sea to save your transportation cost.”
Q4: What is the warranty for your Power Supply?
A: 2 ~ 7 years based on different series.
Q5: What is your payment terms?
A: We accept pay via Bank Transfer, Paypal, Western Union, MoneyGram, Wechat and Alipay.
For better quotations, include:
– A self introduction
– Special requests, if any
We will contact you within 1 working day, please pay attention to the email with the suffix “@jiangtechnology.com” or “@jiangtechnologies.com”.